High-Precision AoA Positioning Base Station from China | Reliable RTLS Suppliers and Factory Solutions

,

The Eforthink AoA High-Precision Positioning Base Station is an essential component of the Henggao RTLS (Real-Time Location System), utilizing advanced AOA (Angle of Arrival) technology to provide outstanding indoor localization accuracy. Manufactured in China, this base station serves as a core RTLS Anchor, strategically deployed in targeted areas to identify and track compatible tags. It is ideal for real-time location systems across various sectors, including healthcare, industrial, and logistics applications.
With its innovative RTLS technology, this base station delivers positional accuracy ranging from 0.2m to 1m and angular precision of 2°, making it perfect for environments that require millimeter-level tracking, such as warehouse inventory systems or hospital safety protocols. Its adaptive coverage radius is based on installation height (H ≤ 10m), achieving a maximum communication range of 200m. As a reliable supplier and factory in the positioning technology market, Eforthink ensures cutting-edge solutions for efficient tracking and location management.

,

    Advantages

    Features

    Parameters

    Application

    Core Technical Advantages

    High-Accuracy Positioning

    Based on AoA technology, the system delivers indoor positioning accuracy of 0.2 m–1 m with angular resolution up to 2°.

    Communication Range

    Up to 200 m line-of-sight communication coverage.

    Scalable Infrastructure

    Supports 1-to-3 cascade deployment via standard PoE, enabling flexible expansion for large-scale RTLS networks.

    Real-Time System Monitoring

    Prioritizes emergency alerts, battery status updates, and dynamic tag management functions such as group calling and individual paging.

    Coverage Scaling

    Positioning coverage scales with installation height (3H coverage diameter, H ≤ 10 m), making it suitable for multi-level industrial facilities.

    High Throughput Performance

    Processes up to 200 tag updates per second, ensuring stable performance in high-density environments such as manufacturing plants.

    Product Features

    Forthink AoA High-Precision Positioning Base Station 4

    Ceiling-mounted deployment ensures optimal signal reception. The base station captures signals from positioning tags and transmits data to a centralized positioning engine. By analyzing azimuth and elevation angles combined with known height data, the system calculates precise indoor coordinates, enabling reliable localization even in obstructed environments.

    Coverage radius is correlated with installation height. For typical indoor deployments (3–5 m mounting height), the high-precision coverage radius is approximately 3–5 m.

    Eforthink AoA High-Precision Positioning Base Station 5

    The base station must be connected to a backend server to enable positioning functions. The server operates in static IP mode and requires manual configuration based on the site network environment. Therefore, the target server IP must be configured on the base station to establish connectivity.

    The device supports two network configuration modes: single-device configuration and batch configuration. In wired mode, only the server address is required for setup.

    Product Parameters

    Product Dimensions 223×220×45mm
    Positioning Technology AOA
    Housing Material PC+ABS
    Power supply mode Standard POE, support 1 drag 3 cascade
    POE Input Voltage 802.3at 36–58V
    Positioning Wireless Standard 802.15.4 2011UWB
    POE Output Voltage (3 Ports) POE Input Voltage -1.4V
    Wired Communication Interface LAN Port (10M/100M Auto-Adaptive)
    Wireless Positioning Standard Wireless Positioning Standard
    Function Configuration Priority to Receive Emergency Help Messages from Tag Cards, Monitor Battery Status of Tag Cards, Perform “Group Call” and “Individual Call”, and Parameter Reset

    Application Scenarios

    Eforthink Hospitalnursing home dormitory presence detection localization

    Healthcare

    Real-time presence detection and indoor positioning in hospital wards and nursing home rooms, enabling accurate staff and patient localization management.

    Eforthink Blind positioning of rooms, nooks, and strongly shaded areas in warehousing and logistics parks

    Logistics

    Non-line-of-sight (NLoS) positioning in warehouses and logistics parks, including rooms, corners, and signal-obstructed areas.

    Eforthink Manufacturing Plant Occluded Area Blind Positioning

    Industrial IoT

    Occluded-area positioning in manufacturing plants, enabling reliable tracking in complex industrial environments with signal blockage.

    Frequently Asked Questions

    What is the positioning accuracy of the AoA base station?
    The base station utilizes advanced Angle of Arrival (AoA) technology to deliver high-accuracy indoor positioning of 0.2 m to 1 m, with an angular resolution of up to 2°.
    What is the maximum coverage and communication range of the base station?
    The base station supports a line-of-sight (LoS) communication range of up to 200 meters. The positioning coverage diameter scales relative to the installation height (3H coverage diameter, where H represents height and is less than or equal to 10 meters).
    How does the PoE cascading feature work?
    The system supports standard PoE (802.3at 36–58V input) and features a 1-to-3 cascade deployment option, which reduces wiring complexity and makes large-scale network expansion more efficient.
    Can the system monitor tag battery status and handle emergencies?
    Yes. The system supports real-time monitoring, prioritizing emergency help messages from tag cards, tracking battery status, and enabling dynamic management features like "Group Call" and "Individual Call."
    What are the primary application scenarios for this positioning system?
    It is ideal for healthcare facilities (patient/staff tracking in wards), logistics parks (non-line-of-sight tracking in rooms and corners), and industrial IoT environments (occluded-area tracking inside manufacturing plants).
    How is the base station configured and connected to the server?
    The base station requires a backend server connection to enable positioning. The server runs in static IP mode, and the target server IP must be configured on the base station. The device supports both single-device and batch configuration modes.